Do you recognise one of these symptoms?
- Both mirror disks are reported as failed
- The mirror broke and one of the disks holds old data
- The resync overwrote the recent data
- The NAS or server no longer boots
Job sheetRAID-1
- Device
- RAID 1 (mirroring)
- Price
- From €350 excl. VAT, fixed quote after diagnosis
- Environment
- ISO 5 cleanroom (class 100) if opening is needed
- Method
- Full image of the device, rebuild on the copy, never on the original
- Turnaround
- Free 10 to 15 working days · Standard 5 to 10 working days · Emergency 1 to 5 working days
- Check
- List of recovered files sent before payment
- Confidentiality
- Data never passed on to third parties, copies deleted after return
The failures we handle
- Second disk failing
- During the resync the remaining disk is read in full: that is often when it gives out.
- Silent desynchronisation
- A disk that dropped out of the mirror long ago holds an old version of the data. The right disk must be identified before anything else.
- Resync error
- A badly done disk replacement can copy the old disk over the newer one.
What not to do
- Do not start a resync if you do not know which disk is the most recent.
- Do not replace both disks at the same time.
Identifying the right disk
We clone both disks and compare the file system journals to work out which holds the most recent data. If both are partly damaged, the readable areas of each are combined into a complete image.
RAID 1 simulator: what happens when a disk fails?
Each block is written identically to both disks. Fault tolerance: 1 disk. Click one or more disks to simulate a failure.
Price of RAID 1 (mirror) data recovery
From €350 excl. VAT, fixed quote after diagnosis. The diagnosis is free and the quote is fixed: it does not change once accepted. If no data is recovered, you pay nothing. See the full price list.