RAID 5 data recovery

RAID 5 spreads data and parity information across all the disks: it survives the loss of one disk, not two. It is the most widely used level in NAS units and small business servers, and the one we handle most often, usually after a rebuild that went wrong.

  • From €350 excl. VAT, fixed quote after diagnosis
  • Free diagnosis
  • €0 if nothing is recovered
Request a free diagnosis

Free and no obligation, reply within 2 hours.
Prefer to write? belgium@recdati.com

Four-disk RAID 5 array in 3D: the data is split into stripes with a parity block; when disk 3 fails, its blocks are recalculated from the other disks.1A1B1C1PD2A2B2PCD13A3A3PBPBC2C2D2D24PAB3C3D3RAID · SAS 12 Gb/sBBUA1 ⊕ A2 ⊕ PA = A3RAID 5 · 4 DISQUESBANDE0x00A3FParity: XOR calculationDisk 3: rebuilt

Do you recognise one of these symptoms?

  • The array is 'degraded' and a second disk is showing errors
  • The rebuild stopped or failed
  • The volume is 'crashed', 'inactive' or 'not mounted'
  • Two disks are reported as failed at the same time
  • The RAID controller was replaced and offers a foreign configuration

Job sheetRAID-5

Device
RAID 5
Price
From €350 excl. VAT, fixed quote after diagnosis
Environment
ISO 5 cleanroom (class 100) if opening is needed
Method
Full image of the device, rebuild on the copy, never on the original
Turnaround
Free 10 to 15 working days · Standard 5 to 10 working days · Emergency 1 to 5 working days
Check
List of recovered files sent before payment
Confidentiality
Data never passed on to third parties, copies deleted after return

The failures we handle

Second failure during the rebuild
The rebuild rereads all the remaining disks: one unreadable sector or a worn disk is enough to interrupt it.
Disk dropped from the array long ago
A disk ejected without warning holds old data; putting it back mixes two versions of the volume.
Controller or NAS failure
The configuration is lost while the disks are intact.
Human error
Healthy disk removed instead of the failed one, array recreated, initialisation.

What not to do

  • Do not restart a rebuild that has already failed.
  • Do not replace a second disk 'just to see'.
  • Do not recreate the array or import a foreign configuration without knowing what it contains.
  • Do not change the order of the disks in the enclosure.

How RAID 5 works

Data is cut into stripes spread over all the disks except one, which receives a parity block calculated with an XOR operation. The parity block moves to a different disk on each row. If a disk disappears, each missing block can be recalculated from the other blocks in the row. Usable capacity is that of all the disks minus one.

With high-capacity disks, the rebuild takes many hours during which the array has no protection at all. That is why RAID 6 is preferable beyond four or five large disks.

How we recover a RAID 5

Every disk is copied, including those reported as failed: even partly readable, they provide information. We then identify the oldest disk, the disk order, stripe size, parity rotation and offset. The array is rebuilt virtually leaving out the out-of-sync disk, and missing sectors on a disk are recalculated from the others. Files are extracted and checked before return.

RAID 5 simulator: what happens when a disk fails?

The data is split into stripes; one parity block (p) per row moves to a different disk on each line. Fault tolerance: 1 disk. Click one or more disks to simulate a failure.

A1B1C1Dp
A2B2CpD1
A3BpC2D2
ApB3C3D3
Healthy volume: all data is accessible.

Price of RAID 5 data recovery

From €350 excl. VAT, fixed quote after diagnosis. The diagnosis is free and the quote is fixed: it does not change once accepted. If no data is recovered, you pay nothing. See the full price list.

Useful guides (in French)

How it works

  1. Free diagnosis

    We analyse your device and identify the exact failure. No obligation.

  2. Fixed quote

    You receive a fixed price and a turnaround time. Nothing is done without your consent.

  3. Recovery

    Work in the lab, on a copy of your device, never on the original.

  4. File list

    You check the list of recovered files before you pay.

  5. Return

    Your data is returned on a new device, together with your original device.

The detailed process, step by step

Frequently asked questions: RAID 5

Can a RAID 5 with two failed disks be recovered?

Very often, yes. Two disks are rarely completely unreadable: the first to drop out of the array usually holds old but usable data, and a disk with a mechanical failure can be repaired in the cleanroom.

How long does it take?

Diagnosis is quick. Recovery takes from a few days to two weeks depending on the number and capacity of the disks and the condition of each.

Should I send all the disks?

Yes, every disk in the array, including those that seem healthy, numbered according to their position.

Device not responding any more? Switch it off and let's talk.

Request a free diagnosis