Do you recognise one of these symptoms?
- The controller reports a degraded or "offline" volume
- The rebuild failed or stopped
- Several disks are marked as failed
- The RAID controller or the server motherboard is out of service
- The volume is visible but the file system is unreadable
Recovery by RAID level
Job sheetRAID
- Device
- RAID
- Price
- From €350 excl. VAT, fixed quote after diagnosis
- Environment
- ISO 5 cleanroom (class 100) if opening is needed
- Method
- Full image of the device, rebuild on the copy, never on the original
- Turnaround
- Free 10 to 15 working days · Standard 5 to 10 working days · Emergency 1 to 5 working days
- Check
- List of recovered files sent before payment
- Confidentiality
- Data never passed on to third parties, copies deleted after return
The failures we handle
- Several disks failing
- Disks in the same array are often the same age: when one fails, another follows during the rebuild.
- Configuration error
- Controller reset, foreign configuration imported, disk reinserted in the wrong slot.
- Controller failure
- Failed RAID card or cache battery: the array metadata becomes inconsistent.
What not to do
- Do not start a new rebuild if a second disk shows signs of weakness.
- Do not initialise the disks or create a new array.
- Label each disk with its position in the server before removing it.
- Do not run CHKDSK or fsck on a degraded RAID volume.
Virtual rebuild of the array
We never repair a RAID "in place". Each disk is cloned, then the array is rebuilt in software: disk order, stripe size, parity rotation, offsets. This lets us test several hypotheses with no risk to the originals.
We support hardware controllers (Dell PERC, HP Smart Array, LSI/Broadcom MegaRAID, Adaptec) and software RAID (Windows Storage Spaces, mdadm, ZFS, Btrfs), as well as VMware VMFS and Hyper-V volumes.
Supported RAID levels
RAID 0 (striping), RAID 1 (mirroring), RAID 5 and 6 (single or double parity), RAID 10, 50, 60 and JBOD. For a two-disk mirror, see the RAID 1 page.
RAID levels compared
| Level | Min. disks | Usable capacity | Fault tolerance | Performance | Typical use |
|---|---|---|---|---|---|
| RAID 0 | 2 | 100 % | None | Excellent | Video editing, cache |
| RAID 1 | 2 | 50 % | 1 disk | Good read | Workstations, small NAS |
| RAID 5 | 3 | (n − 1) / n | 1 disk | Very good read, average write | NAS, file servers |
| RAID 6 | 4 | (n − 2) / n | 2 disks | Very good read, slower write | Large arrays, archiving |
| RAID 10 | 4 | 50 % | 1 per mirror | Excellent | Databases, virtual machines |
Price of RAID data recovery
From €350 excl. VAT, fixed quote after diagnosis. The diagnosis is free and the quote is fixed: it does not change once accepted. If no data is recovered, you pay nothing. See the full price list.
Useful guides (in French)
- The complete guide to RAID
- RAID 10 or RAID 50: which level for a large array?
- JBOD or RAID: which to choose for storing your data?
- What is RAID and how does it work?
- RAID 50 and RAID 60: how they work and which to choose
- RAID servers: three misconceptions to forget
- Which RAID level for your use?
- Symptoms of a failing RAID and what to do
- Striping, mirroring and parity: how RAID spreads your data
- Hardware RAID or software RAID: which to choose?
- RAID of SSDs or of hard drives: which is better?
- AHCI or RAID: which mode to choose in the BIOS?
- How to rebuild a failed RAID without losing your data